Trailer Generator Powered by Cummins
Trailer Generator Powered by Cummins
General Features of Cummins Trailer Generator
1. Composed of Cummins diesel engine and Stamford alternator.
2. 24V DC start motor and storage battery.
3. Brushless, Self-excited, IP23, insulation class H alternator.
4. 40℃ radiator as standard, 50℃ is optional.
5. Key start panel control system as standard, digital auto-start panel is optional.
6. 8-hour operation base tank.
7. All generator sets go through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop).
Reliable Performance of Cummins Trailer Generator
Voltage regulation
Voltage regulation maintained within ±0.5% as follows:
1. Power factor Between 0.8~1.0 lag.
2. From no load to full load, any steady load.
3.Speed droop variation under 4.5%.
Frequency/Speed undulation
1. Change load from 0-100%, Frequency/Speed Droop Ratio within 5%.
2. Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%.
Effect factor of telecom
1. TIF( MA MG1-22) better than 50.
2. THF( BS EN60034) better than 2%.
Criterion
1. ISO8528, GB/T2820.
2. EN12601:2001, EN60034-22:1997, EN60204-1:2006.
3. ISO9001:2000 Quality Control System.
Technical Parameter of Cummins Trailer Generator :
MTG Cummins SERIES - 50Hz
| Genset Model |
Genset Prime Power |
Genset Standby Power |
brand new Cummins Engine |
Engine Max. Power |
brand new Stamford Alternator |
Alternator Prime Power |
| kVA |
kVA |
Model |
kW |
Model |
kVA |
| MTG25CS-1 |
25 |
27 |
4B3.9G1 |
26 |
BCI 184F |
27.5 |
| MTG40CS-1 |
40 |
44 |
4BT3.9G1 |
40 |
BCI 184J |
40 |
| MTG60CS-1 |
60 |
66 |
4BTA3.9G2 |
55 |
UCI 224E |
60 |
| MTG100CS-1 |
100 |
110 |
6BT5.9G2 |
100 |
UCI 274C |
100 |
| MTG140CS-1 |
140 |
154 |
6BTAA5.9G2 |
132 |
UCI 274E |
140 |
| MTG180CS-1 |
180 |
198 |
6CTA8.3G2 |
180 |
UCI 274G |
182 |
| MTG220CS-1 |
220 |
242 |
6CTAA8.3G2 |
207 |
UCI 274J |
230 |
MTG Cummins SERIES - 60Hz
| Genset Model |
Genset Standby Power |
Genset Prime Power |
brand new Cummins Engine |
Engine Max. Power |
brand new Stamford Alternator |
Alternator Prime Power |
| kW |
kW |
Model |
kW |
Model |
kW |
| MTG25CS-2 |
25 |
23 |
4B3.9G1 |
30 |
BCI 184E |
24 |
| MTG38CS-2 |
38 |
35 |
4BT3.9G1 |
45 |
BCI 184H |
37.5 |
| MTG60CS-2 |
60 |
55 |
4BTA3.9G2 |
65 |
UCI 224E |
60 |
| MTG100CS-2 |
100 |
91 |
6BT5.9G2 |
115 |
UCI 274C |
100 |
| MTG130CS-2 |
130 |
118 |
6BTAA5.9G2 |
140 |
UCI 274E |
143 |
| MTG180CS-2 |
180 |
164 |
6CTA8.3G2 |
207 |
UCI 274F |
165 |
| MTG215CS-2 |
215 |
195 |
6CTAA8.3G2 |
230 |
UCI 274H |
204 |